Oferujemy nowoczesne kotłownie kontenerowe – w pełni wyposażone, mobilne systemy grzewcze, które zapewniają szybkie i efektywne dostarczenie ciepła w dowolnym miejscu. Idealne dla przemysłu, budownictwa czy jako rezerwowe źródło energii, nasze kotłownie to gwarancja niezawodności i oszczędności. Sprawdź naszą ofertę i przekonaj się, jak łatwo dostosować mobilne ogrzewanie do swoich potrzeb.
-
-
-
-
-
-
-
ELECTRIC HEATING PLATFORMS
-
-
-
-
-
-
-
-
-
-
-
-
-
HEATING PUMPS
-
-
-
-
-
-
-
-
-
ADDITIONAL ACCESSORIES
-
-
-
INFRARED RADIANT HEATERS
-
-
- MOBILE BOILER ROOMS
- VENTILATION
- SERVICE
- SPARE PARTS
- RENTAL
- OUTLET
- Blog
- CONTACT
MASTER B 9 EPB (9 kW) ELECTRIC HEATER
Portable electric heaters provide the option of heating anywhere (where electricity is available) with immediate effect. They provide a quick increase in temperature in the room, but are also used, for example, during renovation works, effectively supporting the removal of excessive moisture.
Safe and secure shopping
Fast shipping
Satisfaction guaranteed
Master B 9 EPB electric heater (9 kW)
Electric heaters can be used in almost all conditions. Quick installation and high efficiency of the devices mean that the heat in the room is felt immediately after commissioning. Master electric heaters are fully portable and can be used both in offices, apartments and large industrial facilities.
Great mobility
The undoubted advantage of electric heaters is their high mobility - you only need to provide access to the electrical installation, outdoors you can use power from power generators, and thanks to the low weight, you can easily change the heater's place of operation . Compact, metal housing, high efficiency, quiet operation, no exhaust emissions and no oxygen consumption are the features of electric heaters, thanks to which they can be used in rooms where people and animals are present. The fact that no water vapor is released prevents the accumulation of moisture in the rooms and supports their drying.
Improved warm air distribution
In order to better distribute heat in the heated room, models with power from 2.0 kW to 22 kW during operation, continuously force air circulation even when the heating elements are turned off. This allows the air temperature to be equalized in different parts of the room. The heaters are protected against overheating in the form of a manual RESET function. There is a capillary tube temperature sensor in the air outlet cover.
Built-in room thermostat
Master B 9 heaters are equipped with an adjustable thermostat - if the room temperature is lower than that set on the thermostat, the device will start heating. After reaching the temperature set on the thermostat in the room, the device will turn off: the heating elements and the fan will stop working. After the temperature in the room decreases, the device automatically starts heating by switching on the heating elements and the fan.
Adjustable heating power
The heating power is regulated by the main switch, which can be set to 1/2 or 1/1 or power, depending on the model. Models from 2.0 kW to 22 kW can work in fan mode after selecting the mode marked with the fan pictogram by the main switch.
Overheating protection
If the outlet air temperature exceeds 105oC (the temperature is measured by the sensor), the heating elements will be turned off. The fan in the heater will run, the heating elements will remain disconnected. To enable the heaters to work, press the RESET button located on the front panel of the heater, next to the thermostat knob. Heaters B5 5,0 B9 and B15 with a capacity of 5 ; 9 and 15 kW are equipped with manual RESET. In contrast, the B22 kW model has an automatic reset. It differs from manual RESET in that after the device is turned off and it has cooled down, it will automatically reset and the heater will be ready for operation. The most common cause of this function is a power failure during the heater operation, causing the temperature inside the device to rise due to the fan stopping or turning the device off without cooling down for 3 minutes.
Main features
Built-in room thermostat
Power regulation
Stainless steel heating elements
They do not consume oxygen
Motor with thermal switch
Overheating thermostat
Strong and durable steel construction
Model Description:
Attention!
- Built-in room thermostat
- Oxygen-free
- No fumes, odors, no moisture
- Summer-winter switch for ventilation only
- Quiet operation
- Automatic reset Motor with thermal switch
- Heating elements made of stainless steel
- Overheating thermostat
- Adjustable power Strong and durable steel structure
- Do not place blast heaters directly against a wall or other obstruction.
- Do not touch internal parts of the heater.
Application:
warehouses
workshops
construction
renovations
agriculture
TECHNICAL DATA:
Heating power
9,0 kW
Air flow
800 m³/h
Recommended for areas [m2]
90
Minimum heating power
4,5 kW
Tension
400 V / 3-phase
Switch position 1
off
Frequency
50 Hz
Rated current
13,0 A
Thermostat control
YES
Temperature range
5-35 °C
Security
IP 24
Package dimensions (L x W x H)
340x420x440 mm
Case
Metal
Weight in the package
10,3 Kg
Weight
9,3 Kg