Flue gas economizer 6.5 kW - 270m³ / h

Flue gas economizer with a capacity of 6.5 kW - air flow 270 m³ / h, allowing the recovery of up to 40% of the heat escaping to the chimney. Two-way hot air outlet.

help_outlineAsk about product
Flue gas economizer 6.5 kW - 270m³ / h

Flue gas economizer 6.5 kW - 270m³ / h

Flue gas economizer with a capacity of 6.5 kW - air flow 270 m³ / h, allowing the recovery of up to 40% of the heat escaping to the chimney. Two-way hot air outlet.

I accept privacy policy rules  

 

Safe and secure shopping

 

Fast shipping

 

Satisfaction guaranteed

Double-sided flue gas economizer / 6.5 kW recuperator

Double-sided flue gas economizer / recuperator is a device that allows you to recover up to 40% heat that escapes into the chimney. Air flow 270 m³ / h.

Building

The MTM economizer is a compact structure, consisting of a tubular heat exchanger, stainless steel housing and an efficient fan -270 m³ / h.

Action

The hot exhaust gases from the heating device to the chimney pass through the heat exchanger, at the same time heating the clean air taken in from the room. Thanks to the radial fan, the heated air is forced out through two warm air outlets.

The additional heat obtained from the flue gas increases the heating efficiency of the device, thus allowing to heat a larger area or reducing heating costs by reducing the fuel consumption of the heating device.

Connecting the blower channels to the economizer outlets allows the heated air to be directed to adjacent rooms. The shorter the duct section, the greater the efficiency, so it is recommended to use ducts to heat rooms located "through the wall" with the room where the heating device is located, or in a short distance from this room.

The economizer is especially useful for heating social rooms (canteen, cloakroom, etc.), offices or points of sale.

MAIN FEATURES

Efficient fan with air flow of 270 m³ / h

Air regulating flap

Stainless steel housing

Durable construction

Two-way air outlet

Extensive heat exchanger

Recovery up to 40% heat from the flue gas

Destiny:

  • increasing the efficiency of furnaces and heaters,
  • lowering heating costs,
  • heating 1 or 2 additional rooms.


Installation

The economizer should be installed on the vertical section of the exhaust pipe, as close as possible to the flue - the exhaust outlet from the device (where the exhaust gas temperature is the highest).

APPLICATION

  • blast furnaces (MTM 17-33, MTM 8-30, MTM 15-35GT, MTM 30-52, WA29, WA33, WA33A, WA33B, MOTHER, HP 125, HP 115, AT-305, AT-306, AT-307, MTM33, HP-105, HP-115, HP-125, INOP-34, SMH33)
  • MASTER heaters (BV 110 E, BV 170 E, BV 290 E)
  • solid fuel furnaces and other furnaces having a flue gas outlet with a diameter of up to 150 mm

Blowing furnaces

MTM 17-33, MTM 8-30, MTM 15-35GT, MTM 30-52, WA29, WA33, WA33A, WA33B, MAC, HP 125, HP 115, AT-305, AT-306, AT-307, MTM33, HP-105, HP-115, HP-125, INOP-34, SMH33.
SEE IT

MASTER oil heaters

BV 110 E, BV 170 E, BV 290 E
SEE IT

Heaters and solid fuel stoves

Having an exhaust outlet with a diameter of 150 mm
SEE IT

TECHNICAL DATA

Air flow

270 m³ / h

The diameter of the chimney connection

150 mm

The diameter of the hot air outlets

80 mm

Temperature rise

up to 100 ° C

Height

610 mm

Width

370 mm

Depth

420 mm

Weight

8.7 kg